17
SYSTEM 236 Installation Manual
CL 19 and 1A
Command Location 19: Panic Report
0011
(1) (2) (3) (4)
Default Values
19
#
Digit Positions (1) - (2): Panic Report Code
Valid entries are 0 - F
Program a "00" to disable Panic Reports.
Digit Position (3): Panic Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
Digit Positions (4): Panic Audible Type
1 = Pulsing
2 = Steady
3 = Chirp
4 = Silent
Command Location 1A: Test Report
0015
(1) (2) (3) (4)
Default Values
1A
#
Digit Positions (1) - (2): Test Report Code
Valid entries are 0 - F
Program a "00" to disable Test Reports.
Digit Position (3): Test Report Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
Digit Position (4): Test Report Interval
PROGRAMMING CONVERSIONS
Hexadecimal Value
Key Strokes
A
B
C
D
E
F
0
1
2
3
4
5
0 = Manual (See NOTE)
1 = 1 hour
2 = 4 hours
3 = 12 hours
4 = 24 hours
5 = 7 days
6 = 14 days
7 = 30 days
8 = 1 hour, if armed
9 = 4 hours, if armed
0 = 12 hours, if armed
1 = 24 hours, if armed
NOTE: When the Test Report Interval is programmed with a "0", automatic
Test Reporting is disabled. To send a Manual Test Report to the
Central Station, refer to the System Test procedures outlined in the
Keypad End User Manual supplied with this System.