SYSTEM 236 Installation Manual
10
CL 08 and 09
Command Location 08: Panel Control Options
08
001001
(1) (2) (3) (4) (5) (6)
Default Values
#
Digit Position (1): Disable Loop LEDs
0 = No
1 = Yes: shuts zone LEDs off after 5 minutes
Digit Position (2): Faulted Arming Type
0 = Goof-proof: zones must be normal or shunted to arm
1 = Force Arm: faulted zones will be shunted at end of Exit Delay
Digit Position (3): Default Installer Combination
0 = No; this enables the Pirate-Guard
TM
feature for added security
1 = Yes; combination reverts to factory value on power loss
Digit Position (4): Daily Battery Test Enable
0 = No
1 = Yes: tests battery under load every 24 hours
Digit Position (5): Combination Command
0 = No
1 = Yes; requires combination for Bypass, Instant Arm, keypad-activated RPS, and Test (central station and bell)
Command Location 09: Telco Control Options
09
111101
(1) (2) (3) (4) (5) (6)
Default Values
#
Digit Position (1): Local System Only
0 = No
1 = Yes: disables all communications except RPS
Digit Position (2): Dialing Attempts
0 = 4 attempts
1 = 8 attempts
2 = 14 attempts
Digit Position (3): RPS Enable
0 = No
1 = Yes: allows remote programming to start from off-premise location
Digit Position (4): Enable Keypad RPS
0 = No
1 = Yes: allows remote programming to start from on-site keypad command
Digit Position (5): Phone Ring Type
0 = Single ring; uniformly timed rings with long pauses between rings
1 = Double ring; rings twice quickly followed by a long pause then rings twice again
Digit Position (6): Dial Type
0 = Touch Tone* DTMF
1 = Pulse Dialing
*Touch Tone is a trademark of AT&T
Digit Position (6): AC Line Frequency
0 = 50 Hz
1 = 60 Hz
*Pirate Guard is a trademark of C&K Systems, Inc.