SYSTEM 236 Installation Manual
Table of Contents
Subject Page No.
System 236 Terminal Label Front Cover
UL Compliance 2
Installation 2 - 3
Wiring the Panel 3 - 4
System Start-Up 4
Keypad Setup 4 - 5
Addressing Keypads 5
Factory Default Settings 5
Programming Options (Alphabetical List) 5 - 6
Programming the Panel 6 - 7
Programming with the LED Keypad 6
Programming with the Alpha Keypad 6
Entering Hexidecimal Numbers 7
Programming the Alpha Keypad 7 - 8
Programming Letters & Numbers 7
Special Function Keys 8
Programming Options (Numerical Order) 9 - 23
Keypad Label Drawer 24
Telephone Line Problems 24
Watchdog Indicator 25
Keypad Operation Command Summary 25
Help with Common Problems (Troubleshooting) 26 - 27
Reducing False Alarms 28
Warranty Information 28
Programming Worksheets 29 - 32
BEFORE YOU START
Scope of This Manual
This manual contains basic installation and programming information for
the SYSTEM 236 control/communicator. For detailed information about
remote programming, please refer to the Commander II/Monitor II Oper-
ating Manual (P/N 5-051-221-00).
Accuracy
This manual has been carefully checked for accuracy. However, C&K
SYSTEMS assumes no liability for inaccuracies or actions resulting from
the use of this manual. In addition, C&K reserves the right to modify the
SYSTEM 236 hardware, software, and manuals without prior notice.
UL COMPLIANCE
The SYSTEM 236 is in compliance with Underwriters Laboratories, Inc.
Standards UL 985, Household Warning System Units; UL 1023, House-
hold Burglar Alarm System Units; and UL 1635, Digital Burglar Alarm
Communicator System Units. The following programming restric-
tions must be observed to meet UL standards:
UL Compliance (continued)
1. The audible must be programmed to sound at least four
minutes before silencing.
2. No zone may be programmed for silent alarm.
3. Fire zones must be programmed for pulsing audible alarm.
4. Burglar zones must be programmed for a steady audible.
5. Burglar loops (non-24-hour loops) must be programmed
for NO/NC.
6. No Entry Delay may be greater than 45 seconds.
7. No Exit Delay may be greater than 60 seconds.
8. The Dynamic Battery Test must be enabled.
9. The Unit Status Report must be enabled.
10. The 24-hour Check-in must be enabled.
11. No Delay Before Dial may be programmed for the
communicator.
12. The unit must not be programmed to dial a police station.
13. Use screws (supplied) to secure cover or a lock must be
installed on the cabinet.
14. All devices must be UL listed.
15. Loop Response Time must be set to 500mS.
Mounting
The SYSTEM 236 should be mounted in a location which allows conve-
nient access to AC power, telephone connections, and earth ground.
Remove the circuit board from the cabinet. This will prevent
possible damage to the circuit board when removing the knock-
outs.
Remove the knock-outs.
Mark the screw mounting holes on the wall.
INSTALLATION
.
.
.
Mount the cabinet at the desired height and pass the cables
through the knock-outs.
.
.
.
Replace the circuit board, remembering to connect the ground lug
to the lower left corner of the circuit board.
Reconnect the spade lug to the lower door hinge. This provides
the earth ground connection for the door.
Earth Ground
To ensure the effectiveness of the lightning and transient protection
circuits, the control panel must be connected to "Earth Ground". Ideally,
this should be a common ground to the power lines, telephone system, and
security system. This type of ground, called a "Unified Earth Ground",
provides the best protection. The ground connection, from a grounding
rod, cold water pipe or other established ground point, is made to the green
jacketed wire providing a ground to the panel housing.
Zone Programming
FIRE LOOP BURGLAR LOOP
No Delay Before Dial
.
No Delay Before Dial
.
24-hour arming
.
Pulsing audible
.
Supervised
- latching for heat
- resetting for smoke
.
Not shuntable
.
.
.
NO/NC with EOL
Keypad Requirements
The keypad may not have the EMERGENCY symbol ( ) on it.
If your keypad has this symbol, remove the key and replace it with
one of the blank keys provided.
Steady audible
500mS Loop Response Time
500mS Loop Response Time
.
.