1:0. SETTING THE SYSTEM
To arm the system enter your user code. The exit tone from any extension
speakers start at a low volume level, as well as sound from the keypads.
The speaker volume increases after 5 seconds. Any pulsed tones should
return to a continuous tone once you have left the building and the sensors
have cleared. The control panel arms after the exit timer runs out. At this
point the tone should cease. If for any reason the tone does not go continu-
ous after all the sensors clear, return back to the panel or remote keypad
and press # to abort the setting procedure. If the internal sounder activates
after the timer expires, return back to the control panel or any remote
keypad and insert your user code and press #. (Refer to fault clearing in
Section 13:0.)
1:1. Selecting Full Set
No further action is required; leave the premises by the authorised exit
route.
1:2. Selecting Night Set
Press * then 0. The zones pre-programmed to be isolated start to flash. Any
extension speakers and any remote keypads emit a low pitch continuous
tone. Provided night set is selected, within 5 seconds the exit sounder
remains at low volume. This level is adjustable by your installer. If the
installer has programmed the panel for instant night set, the system arms as
soon as you make the selection.
1:3. Selecting Home Set
Press * then 8. This isolates any chosen zones programmed for isolation.
Please note that this setting method can allow the isolation of ALL entry
routes. Follow the above paragraph for guidance regarding exit tones.
2:0. MANUAL ISOLATION OF ALARM ZONES
There may be occasions when you need to isolate zones other than the
zones pre-programmed. Arm the system as above. Then press * and the
zone number you want to isolate. That zone flashes indicating a successful
isolation. If you want more zones isolated, press * and another zone. If any
zone is barred from isolation, an error tone is emitted.
Zones that cannot be isolated:
Fire
PA
Tamper
Zone 1 in Full Set
Zone 8
SETTING THE
SYSTEM
FULL SET
NIGHT SET
HOME SET
ZONE
ISOLATION